Nissan Juke Service and Repair Manual : Symptom diagnosis
- Door does not lock/unlock with door key cylinder operation
- Door does not lock/unlock with door lock and unlock switch
- Door does not lock/unlock with keyfob
- Door lock status indicator does not illuminate
- Super lock does not operatE
- Back door does not opened
- ANTI-HIJACK function does not operate
- Vehicle speed sensing auto lock operation does not operate
- IGN off interlock door unlock function does not operate
- P range interlock door lock/unlock function does not operate
- Auto door lock operation does not operate
- Door lock status indicator does not illuminate
- Unlock link function does not operate
- Key out interlock door unlock function does not operate
- Key reminder function does not operate
- Hazard reminder operation does not operate
- Squeak and rattle trouble diagnoses
Unlock sensor
Component Function Check
1.CHECK FUNCTION
1. Select “DOOR LOCK” of “BCM” using CONSULT-III.
2. Select “LOCK STATUS” in “DATA MONITOR” mode.
3. Check that the function operates normally according t ...
Door does not lock/unlock with door key cylinder operation
Diagnosis Procedure
1.CHECK POWER DOOR LOCK OPERATION
Check power door lock operation.
Does door lock/unlock with door lock and unlock switch?
YES >> GO TO 2.
NO >> Go to DLK-415, ...
Other materials:
Vehicle jerks during
Description
The vehicle jerks when ESP function, TCS function, ABS function, EBD function
or brake limited slip differential
(BLSD) function operates.
Diagnosis Procedure
1.CHECK SYMPTOM
Check that the vehicle jerks when ESP function, TCS function, ABS function,
EBD function or brake limite ...
Wiring diagram
METER SYSTEM
Wiring Diagram
For connector terminal arrangements, harness layouts, and alphabets in a
(option abbreviation; if not
described in wiring diagram), refer to GI-12, "Connector Information/Explanation
of Option Abbreviation".
...
Park/neutral position (PNP) switch : Component Inspection
1.CHECK PARK/NEUTRAL POSITION (PNP) SWITCH
1. Disconnect position switch connector. Refer to TM-77, "Removal and
Installation".
2. Check continuity between position switch terminals.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace position switch ...