Nissan Juke Service and Repair Manual : Auto door lock operation does not operate

Diagnosis Procedure

1.CHECK “AUTO LOCK SET” SETTING IN “WORK SUPPORT

1. Select “INTELLIGENT KEY” of “BCM” using CONSULT-III.

2. Select “AUTO LOCK SET” in “WORK SUPPORT” mode.

3. Check “AUTO LOCK SET” in “WORK SUPPORT”.

Refer to DLK-43, "INTELLIGENT KEY : CONSULT-III Function (BCM - INTELLIGENT KEY) (With Super Lock)".

Is the inspection result normal? YES >> GO TO 2.

NO >> Set “AUTO LOCK SET” setting in “WORK SUPPORT”.

2.REPLACE BCM

1. Replace BCM. Refer to BCS-93, "Removal and Installation".

2. Confirm the operation after replacement.

Is the result normal? YES >> INSPECTION END

NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

    Back door does not opened
    Diagnosis Procedure 1.CHECK BACK DOOR OPENER SWITCH Check back door opener switch. Refer to DLK-69, "Component Function Check". Is the inspection result normal? YES >> GO TO 2 ...

    Vehicle speed sensing auto lock operation does not operate
    Diagnosis Procedure 1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC LOCK/UNLOCK SELECT” i ...

    Other materials:

    Thermo control amplifier
    Removal and Installation REMOVAL 1. Remove evaporator. • Refer to HA-55, "EVAPORATOR : Removal and Installation". (HR16DE) • Refer to HA-115, "EVAPORATOR : Removal and Installation". (MR16DDT) 2. Remove the thermo control amp. from evaporator. INSTALLATION Note the ...

    Recommended fluids/lubricants and capacities
    The following values represent approximate capacities for your Nissan Leaf. Please note that actual refill volumes can vary slightly depending on environmental conditions and service methods. When performing a fluid change, always follow the specific procedures described in the "Do-it-yourself" sect ...

    Park/neutral position (PNP) switch : Component Inspection
    1.CHECK PARK/NEUTRAL POSITION (PNP) SWITCH 1. Disconnect position switch connector. Refer to TM-77, "Removal and Installation". 2. Check continuity between position switch terminals. Is the inspection result normal? YES >> INSPECTION END NO >> Replace position switch ...