Nissan Juke Service and Repair Manual : Thermo control amplifier

Removal and Installation

REMOVAL

1. Remove evaporator. Refer to HA-115, "EVAPORATOR : Removal and Installation".

2. Remove thermo control amp. from evaporator.

INSTALLATION

Note the following items, and then install in the reverse order of removal.

CAUTION:
• Replace O-ring with new one. Then apply compressor oil to them when installing.

• When install the thermo control amp., set the same position before replacement.

• When remove the thermo control amp., never turn the bracket which is equipped the top of the thermo control amp.

• Check for the leakages when recharging refrigerant. Refer to HA-74, "Leak Test".

    A/C control
    Exploded View 1. Intake door cable 2. Mode door cable 3. A/C control 4. Air mix door cable 5. Intake door lever knob A. To mode door link B. To intake door link C. To air mix door link ...

    Refrigerant pressure sensor
    Exploded View Refer to HA-94, "Exploded View". Removal and Installation REMOVAL Refer to HA-96, "REFRIGERANT PRESSURE SENSOR : Removal and Installation". INSTALLATION Insta ...

    Other materials:

    P1225 TP sensor
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test. TESTING CONDITION: Before performing the following proced ...

    P0705 transmission range switch A
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE CAUTION: Be careful of the driving speed. 1.PREPARATION BEFORE WORK If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at least 10 seconds, then perform the next test. > ...

    Radiator cap : Inspection
    • Check valve seat (A) of radiator cap. B : Metal plunger - Check that valve seat is swollen to the extent that the edge of the plunger cannot be seen when watching it vertically from the top. - Check that valve seat has no soil and damage. • Pull negative-pressure valve to open it, and that ...