Nissan Juke Service and Repair Manual : Shift P warning lamp

Component Function Check

1.CHECK FUNCTION

1. Select “INTELLIGENT KEY” of “BCM” using CONSULT-III.

2. Select “LCD” in “ACTIVE TEST” mode.

3. Check that the function operates normally according to the following conditions.

Is the inspection result normal?


Is the inspection result normal? YES >> Shift P warning lamp is OK.

NO >> Refer to DLK-98, "Diagnosis Procedure".

Diagnosis Procedure

1.CHECK SHIFT P WARNING LAMP

Refer to MWI-22, "On Board Diagnosis Function".

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace the malfunctioning parts.

2.CHECK INTERMITTENT INCIDENT

Refer to GI-42, "Intermittent Incident".

>> INSPECTION END

    Remote keyless entry receiver
    Component Function Check 1.CHECK FUNCTION 1. Select “INTELLIGENT KEY” of “BCM” using CONSULT-III. 2. Select “RKE OPE COUN1” in “DATA MONITOR” mode. 3. Check that the function operates normally acc ...

    Super lock actuator
    Driver side : Component Function Check 1.CHECK FUNCTION 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “SUPER LOCK” in “ACTIVE TEST” mode. 3. Check that the function operates normally ...

    Other materials:

    P1643 thermoplunger control unit
    DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1.CHECK THERMOPLUNGER CONTROL UNIT POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect thermoplunger control unit harness connector. 3. Check the voltage between thermoplunger control unit harness connector and ground. Is the ...

    P position warning does not operate
    Diagnosis Procedure 1.CHECK DTC WITH BCM, TCM AND COMBINATION METER Check that DTC is not detected with BCM, TCM and combination meter. Is the inspection result normal? YES >> GO TO 2. NO-1 >> Refer to BCS-67, "DTC Index". (BCM) NO-2 >> Refer to TM-171, "DT ...

    DTC/Circuit diagnosis
    POSITION SWITCH BACK-UP LAMP SWITCH : Component Inspection 1.CHECK BACK-UP LAMP SWITCH 1. Disconnect position switch connector. Refer to TM-24, "Removal and Installation". 2. Check continuity between position switch terminals. Is the inspection result normal? YES >> INSPE ...