Nissan Juke Service and Repair Manual : L terminal circuit (short)

Description

The “L” terminal circuit controls the charge warning lamp. The charge warning lamp illuminates when the ignition switch is set to ON or START. When the alternator is providing sufficient voltage with the engine running, the charge warning lamp will go off. If the charge warning lamp illuminates with the engine running, a malfunction is indicated.

Diagnosis Procedure

1.CHECK “L” TERMINAL CIRCUIT (SHORT)

1. Turn ignition switch OFF.

2. Disconnect alternator connector.

3. Turn ignition switch ON.

Does charge warning lamp illuminate? YES >> GO TO 2.

NO >> Refer to CHG-12, "GASOLINE ENGINE MODELS : Work Flow" (gasoline engine models) or CHG-15, "DIESEL ENGINE MODELS : Work Flow" (diesel engine models).

2.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)

1. Turn the ignition switch OFF.

2. Disconnect the battery cable from the negative terminal.

3. Disconnect combination meter connector.

4. Check continuity between combination meter harness connector and ground.

Is the inspection result normal?


Is the inspection result normal? YES >> Replace combination meter.

NO >> Repair the harness.

    L terminal circuit (open)
    Description The “L” terminal circuit controls the charge warning lamp. The charge warning lamp illuminates when the ignition switch is set to ON or START. When the alternator is providing sufficie ...

    S terminal circuit
    Description The output voltage of the alternator is controlled by the IC voltage regulator at the “S” terminal detecting the input voltage. The “S” terminal circuit detects the battery voltage ...

    Other materials:

    Brake fluid
    Inspection BRAKE FLUID LEVEL • Check that the fluid level in the reservoir tank is within the specified range (MAX – MIN lines). • Visually check for any brake fluid leakage around the reservoir tank. • Check the brake system for any leakage if the fluid level is extremely low (lower than MIN ...

    A/C on signal
    Component Function Check 1.CHECK A/C ON SIGNAL With CONSULT-III 1. Turn ignition switch ON. 2. Operate blower motor. 3. Select “AIR CONDITIONER” of “BCM” using CONSULT-III. 4. Select “AIR COND SW” in “DATA MONITOR” mode. 5. Check A/C ON signal when the A/C switch is operated. Is the inspec ...

    Service data and specifications (SDS)
    Compressor Lubricant Refrigerant Engine Idling Speed Refer to EC-807, "Idle Speed". Belt Tension Refer to EM-154, "Checking". ...