Nissan Juke Service and Repair Manual : The fuel gauge indicator does not operate
Description
Fuel gauge will not indicate from a certain position.
Diagnosis Procedure
1.CHECK COMBINATION METER OUTPUT SIGNAL
1. Connect CONSULT-III.
2. Select the “Data Monitor� for the “METER/M&A� and compare the “FUEL METER� monitor value with the fuel gauge reading on the combination meter. Refer to MWI-52, "Component Function Check".
Does monitor value match fuel gauge reading? YES >> GO TO 2.
NO >> Replace combination meter. Refer to MWI-69, "Removal and Installation".
2.CHECK FUEL LEVEL SENSOR SIGNAL CIRCUIT
Check the fuel level sensor signal circuit. Refer to MWI-52, "Diagnosis Procedure".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair harness or connector.
3.CHECK FUEL LEVEL SENSOR UNIT
Perform a unit check for the fuel level sensor unit. Refer to MWI-54, "Component Inspection".
Is the inspection result normal? YES >> GO TO 4.
NO >> Replace fuel level sensor unit (main or sub). Refer to FL-6, "2WD : Removal and Installation" (MR16DDT) (2WD), FL-11, "4WD : Removal and Installation" (MR16DDT) (4WD), FL-33, "Removal and Installation" (HR16DE), or FL-51, "Removal and Installation" (K9K).
4.CHECK FLOAT INTERFERENCE
Check that the float arm interferes with or binds to other components in the fuel tank.
Is the inspection result normal? YES >> Replace combination meter. Refer to MWI-69, "Removal and Installation".
NO >> Repair or replace malfunctioning parts.
The oil pressure warning lamp does not turn on
Description
The oil pressure warning lamp stays off when the ignition switch is turned
ON.
Diagnosis Procedure
1.CHECK OIL PRESSURE WARNING LAMP
Perform auto active test. Refer to PCS-12, " ...
Other materials:
Turn signal lamp circuit
Component Function Check
1.CHECK TURN SIGNAL LAMP
CONSULT-III ACTIVE TEST
1. Select “FLASHER� of BCM (FLASHER) active test item.
2. With operating the test items, check that the turn signal lamps is turned ON.
LH : Turn signal lamps (LH) ON
RH : Turn signal lamps (RH) ON
Off : Turn signal ...
Diagnosis and repair work flow
Work Flow
DETAILED FLOW
1.INTERVIEW FROM THE CUSTOMER
Clarify customer complaints before inspection. First of all, perform an
interview utilizing BRC-146, "Diagnostic
Work Sheet" and reproduce the symptom as well as fully understand it. Ask
customer about his/her complaints
carefu ...
Remote keyless entry receiver
Component Function Check
1.CHECK FUNCTION
1. Select “INTELLIGENT KEY� of “BCM� using CONSULT-III.
2. Select “RKE OPE COUN1� in “DATA MONITOR� mode.
3. Check that the function operates normally according to the following
conditions.
Is the inspection result normal?
YES >& ...