Nissan Juke Service and Repair Manual : SRS air bag warning lamp does not turn on

Diagnosis Procedure

1.CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUIT

Check conbination meter unit power supply and ground circuit. Refer to MWI-51, "COMBINATION METER : Diagnosis Procedure".

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace the malfunctioning parts.

2.CHECK HARNESS CONNECTOR

Check the harness connector.

Is the inspection result normal? YES >> GO TO 3.

NO >> Replace harness connectors.

3.CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal? YES >> GO TO 4.

NO >> Replace wiring harness.

4.CHECK AIR BAG DIAGNOSIS SENSOR UNIT

Disconnect air bag diagnosis sensor unit connector and turn ignition switch ON.

Does air bag warning lamp turn ON? YES >> Replace air bag diagnosis sensor unit. Refer to SR-30, "Removal and Installation".

NO >> Replace combination meter. Refer to MWI-69, "Removal and Installation".

    SRS air bag warning lamp does not turn off
    Diagnosis Procedure 1.CHECK AIR BAG MODULE AND SEAT BELT PRE-TENSIONER Check the deployment of air bag module. Is air bag module deployed? YES >> Replace the malfunctioning parts. NO &g ...

    Other materials:

    Control valve
    Exploded View COMPONENT PARTS LOCATION 1. Transaxle assembly 2. Control valve 3. Bracket 4. O-ring 5. Oil strainer assembly 6. Magnet 7. Drain plug gasket 8. Drain plug 9. Oil pan mounting bolt 10. Oil pan 11. Oil pan gasket 12. Lock nut 13. Washer 14. Manual plate 15. Co ...

    P0078 EVT control solenoid valve
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test. 1. Turn ignition switch OFF and wait at least 10 seconds. 2. Turn ignition swit ...

    Shift P warning lamp
    Component Function Check 1.CHECK FUNCTION 1. Select “INTELLIGENT KEY” of “BCM” using CONSULT-III. 2. Select “LCD” in “ACTIVE TEST” mode. 3. Check that the function operates normally according to the following conditions. Is the inspection result normal? YES >> Shift P warning lamp is ...