Nissan Juke Service and Repair Manual : SRS air bag warning lamp does not turn off

Diagnosis Procedure

1.CHECK AIR BAG MODULE AND SEAT BELT PRE-TENSIONER

Check the deployment of air bag module.

Is air bag module deployed? YES >> Replace the malfunctioning parts.

NO >> GO TO 2.

2.CHECK AIR BAG FUSE

Check 10 A fuse [No.2, located in fuse block (J/B)].

Is the inspection result normal? YES >> GO TO 3.

NO >> Replace the fuse.

3.CHECK HARNESS CONNECTOR

Check the harness connector.

Is the inspection result normal? YES >> GO TO 4.

NO >> Replace harness connectors.

4

.CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal? YES >> GO TO 5.

NO >> Replace wiring harness.

5.REPLACE AIR BAG DIAGNOSIS SENSOR UNIT

1. Replace air bag diagnosis sensor unit. Refer to SR-30, "Removal and Installation".

2. Check air bag warning lamp operation.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 6.

6.REPLACE COMBINATION METER

1. Replace combination meter. Refer to MWI-69, "Removal and Installation".

2. Check air bag warning lamp operation.

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 1.

    SRS air bag warning lamp does not turn on
    Diagnosis Procedure 1.CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUIT Check conbination meter unit power supply and ground circuit. Refer to MWI-51, "COMBINATION METER : Diagnosis Pr ...

    Other materials:

    Radiator
    Exploded View 1. Cooling fan assembly 2. Mounting rubber (upper) 3. Radiator 4. Mounting rubber (lower) 5. O-ring 6. Drain plug 7. Clamp 8. Radiator hose (lower) (LH) 9. Reservoir tank hose 10. Reservoir tank 11. Reservoir tank cap 12. Clamp 13. Radiator hose (upper) 14. Water ...

    Precaution Necessary for Steering Wheel Rotation after Battery Disconne
    NOTE: • Before removing and installing any control units, first turn the ignition switch to the LOCK position, then disconnect both battery cables. • After finishing work, confirm that all control unit connectors are connected properly, then re-connect both battery cables. • Always us ...

    Squeak and rattle trouble diagnoses
    Work Flow CUSTOMER INTERVIEW Interview the customer if possible, to determine the conditions that exist when the noise occurs. Use the Diagnostic Worksheet during the interview to document the facts and conditions when the noise occurs and any of customer's comments; refer to DLK-302, &quo ...