Nissan Juke Service and Repair Manual : Refrigerant pressure sensor

Component Function Check

1.CHECK REFRIGERANT PRESSURE SENSOR OVERALL FUNCTION

1. Start engine and warm it up to normal operating temperature.

2. Turn A/C switch and blower fan switch ON.

3. Check the voltage between ECM harness connector and ground.

Is the inspection result normal?


Is the inspection result normal? YES >> INSPECTION END

NO >> Go to EC-790, "Diagnosis Procedure".

Diagnosis Procedure

1.CHECK GROUND CONNECTION

1. Turn A/C switch and blower fan switch OFF.

2. Stop engine.

3. Turn ignition switch OFF.

4. Check ground connection E38. Refer to Ground Inspection in GI-44, "Circuit Inspection".

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace ground connection.

2.CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT

1. Disconnect refrigerant pressure sensor harness connector.

2. Turn ignition switch ON.

3. Check the voltage between refrigerant pressure sensor harness connector and ground.

Is the inspection result normal?


Is the inspection result normal? YES >> GO TO 4.

NO >> GO TO 3.

3.DETECT MALFUNCTIONING PART

Check the following.

• Harness for open or short between ECM and refrigerant pressure sensor

>> Repair open circuit or short to ground or short to power in harness or connectors.

4.CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT

1. Turn ignition switch OFF.

2. Disconnect ECM harness connector.

3. Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.

4. Also check harness for short to ground and short to power.


4. Also check harness for short to ground and short to power.

Is the inspection result normal? YES >> GO TO 6.

NO >> GO TO 5.

5.DETECT MALFUNCTIONING PART

Check the following.

• Harness for open or short between ECM and refrigerant pressure sensor

>> Repair open circuit or short to ground or short to power in harness or connectors.

6.CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT

1. Check the continuity between ECM harness connector and refrigerant pressure sensor harness connector.

2. Also check harness for short to ground and short to power.


2. Also check harness for short to ground and short to power.

Is the inspection result normal? YES >> GO TO 8.

NO >> GO TO 7.

7.DETECT MALFUNCTIONING PART

Check the following.

• Harness for open or short between ECM and refrigerant pressure sensor

>> Repair open circuit or short to ground or short to power in harness or connectors.

8.CHECK INTERMITTENT INCIDENT

Refer to GI-42, "Intermittent Incident".

Is the inspection result normal? YES >> Replace refrigerant pressure sensor.

NO >> Repair or replace.

    Malfunction indicator
    Component Function Check 1.CHECK MI FUNCTION 1. Turn ignition switch ON. 2. Make sure that MI lights up. Is the inspection result normal? YES >> INSPECTION END NO >> Go to EC-789, ...

    Speed limiter main switch
    Component Function Check 1.CHECK SPEED LIMITER MAIN SWITCH FUNCTION With CONSULT-III 1. Turn ignition switch ON. 2. Select “ENGINE” using CONSULT-III. 3. Select “SL MAIN SW” in “DATA MONITOR” mod ...

    Other materials:

    Throttle valve closed position learning
    Description Throttle Valve Closed Position Learning is a function of ECM to learn the fully closed position of the throttle valve by monitoring the throttle position sensor output signal. It must be performed each time the harness connector of the electric throttle control actuator or ECM is ...

    P158A ECM
    DTC Logic *: Since this DTC is detected when G sensor calibration is incomplete, there is not replacement parts. 1.PRECONDITIONING If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test. 1. Turn ignition swit ...

    P0225 APP sensor
    DTC Logic DTC DETECTION LOGIC NOTE: • If DTC P0225 is displayed with DTC P0641, first perform trouble diagnosis for DTC P0641. Refer to EC-974, "DTC Logic". Diagnosis Procedure 1.CHECK GROUND CONNECTIONS 1. Turn ignition switch OFF. 2. Check ground connection E38. Refer to Grou ...