Nissan Juke Service and Repair Manual : Door lock operation warning does not operate

Diagnosis Procedure

1.CHECK DOOR LOCK FUNCTION

Check door lock function.

Does door lock/unlock using door request switch? YES >> GO TO 2.

NO >> Refer to DLK-85, "Component Function Check".

2.CHECK INTELLIGENT KEY WARNING BUZZER

Check Intelligent Key warning buzzer.

Refer to DLK-92, "Component Function Check".

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace the malfunctioning parts.

3.REPLACE BCM

1. Replace BCM. Refer to BCS-93, "Removal and Installation".

2. Confirm the operation after replacement.

Is the result normal? YES >> INSPECTION END

NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

    Intelligent key low battery warning does not operate
    Diagnosis Procedure 1.CHECK DTC WITH BCM AND COMBINATION METER Check that DTC is not detected with BCM and combination meter. Is the inspection result normal? YES >> GO TO 2. NO-1 >& ...

    Key ID warning does not operate
    Diagnosis Procedure 1.CHECK DTC WITH BCM AND COMBINATION METER Check that DTC is not detected with BCM and combination meter. Is the inspection result normal? YES >> GO TO 2. NO-1 >& ...

    Other materials:

    P0710 transmission fluid temperature sensor A
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE CAUTION: Always drive vehicle at a safe speed. NOTE: If “DTC CONFIRMATION PROCEDURE” has been previously performed, always turn ignition switch OFF and wait at least 10 seconds before performing the next test. After the repair, p ...

    P1805 brake switch
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PERFORM DTC CONFIRMATION PROCEDURE 1. Turn ignition switch ON. 2. Fully depress the brake pedal for at least 5 seconds. 3. Erase the DTC. 4. Check 1st trip DTC. Is 1st trip DTC detected? YES >> Proceed to EC-374, "Dia ...

    Power supply and ground circuit
    Diagnosis Procedure 1.CHECK GROUND CONNECTION 1. Turn ignition switch OFF. 2. Check ground connection E21 and E38. Refer to Ground Inspection in GI-44, "Circuit Inspection". Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace ground connection. ...