Nissan Juke Service and Repair Manual : Does not operate

Description

ABS function and EBD function does not operate.

Diagnosis Procedure

CAUTION:
ABS function and EBD function never operate when the vehicle speed is 10 km/h (6.2 MPH) or les

s.

1.CHECK ABS WARNING LAMP

Check that ABS warning lamp and brake warning lamp turn ON and turn OFF approx. 1 second after key switch is turned ON. Check that ABS warning lamp and brake warning lamp and stay in OFF status during driving.

CAUTION:
Brake warning lamp turns ON when parking brake is operated (parking brake switch is ON) or brake fluid is less than the specified level (brake fluid level switch is ON).

Is the inspection result normal? YES >> Normal

NO >> Perform self-diagnosis for “ABS” with CONSULT-III.

    The braking distance is long
    Description Brake stopping distance is long when ABS function is operated. Diagnosis Procedure CAUTION: Brake stopping distance on slippery road like rough road, gravel road or snowy road may be ...

    Brake pedal vibration or operation sound occurs
    Description • Brake pedal vibrates and motor sound from ABS actuator and electric unit (control unit) occurs, when the engine starts. • Brake pedal vibrates during braking. CAUTION: Vibration ...

    Other materials:

    Service data and specifications (SDS)
    SERVICE DATA AND SPECIFICATIONS (SDS) Idle Speed *: Under the following conditions • A/C switch: OFF • Electric load: OFF (Lights, heater fan & rear window defogger) • Steering wheel: Kept in straight-ahead position Ignition Timing *: Under the following conditions • A/C switch: OFF ...

    B1179 lap Pre-tensioner RH
    DTC Logic DTC CONFIRMATION PROCEDURE 1.CHECK SELF-DIAGNOSTIC RESULT With CONSULT-III 1. Turn ignition switch ON. 2. Perform “Self Diagnostic Result” mode of “AIR BAG” using CONSULT-III. Without CONSULT-III 1. Turn ignition switch ON. 2. Check the air bag warning lamp status. Refer to SRC ...

    Interior room lamp control circuit
    Description Controls each interior room lamp (ground side) by PWM signal. NOTE: PWM signal control period is approximately 250 Hz (in the gradual brightening/dimming). Component Function Check CAUTION: Before performing the diagnosis, check that the following are normal. • Interior room l ...