Nissan Juke Service and Repair Manual : Performance test

Inspection

INSPECTION PROCEDURE

1. Connect recovery/recycling/recharging equipment (for HFC-134a) or manifold gauge.

2. Start the engine, and set to the following condition.

Test condition

3. Maintain test condition until A/C system becomes stable. (Approximately 10


3. Maintain test condition until A/C system becomes stable. (Approximately 10 minutes)
4. Check that test results of “recirculating-to-discharge air temperature” and “ambient air temperature-tooperating pressure” are within the specified value.

5. When test results are within the specified value, inspection is complete.

If any of test result is out of the specified value, perform diagnosis by gauge pressure. Refer to HA-28, "Symptom Table".

RECIRCULATING-TO-DISCHARGE AIR TEMPERATURE TABLEAMBIENT AIR TEMPERATURE-TO-OPERATING PRESSURE TABLE


AMBIENT AIR TEMPERATURE-TO-OPERATING PRESSURE TABLE

Symptom diagnosis


    Lubricant
    Description MAINTENANCE OF LUBRICANT LEVEL The compressor lubricant is circulating in the system together with the refrigerant. It is necessary to fill compressor with lubricant when replacing A/ ...

    Other materials:

    P1553 battery current sensor
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING If DTC Confirmation Procedure has been previously conducted, always perform the following before conducting the next test. 1. Turn ignition switch OFF and wait at least 10 seconds. 2. Turn ignition switch ON. 3. ...

    System
    System Diagram System Description REFRIGERANT CYCLE Refrigerant Flow The refrigerant from the compressor, flows the condenser with liquid tank, the evaporator, and returns to the compressor. The refrigerant evaporation in the evaporator is controlled by an expansion valve. Freeze Prote ...

    P1642 thermoplunger control unit
    DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1.CHECK THERMOPLUNGER CONTROL UNIT POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect thermoplunger control unit harness connector. 3. Check the voltage between thermoplunger control unit harness connector and ground. Is the ...