Nissan Juke Service and Repair Manual : C1604 torque sensor

DTC Logic

DTC DETECTION LOGI

DTC CONFIRMATION PROCEDURE


DTC CONFIRMATION PROCEDURE

1.PRECONDITIONING

If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.

>> GO TO 2.

2.DTC REPRODUCTION PROCEDURE

1. Turn the ignition switch OFF to ON.With CONSULT-III


1. Turn the ignition switch OFF to ON.

2. Perform “EPS” self-diagnosis.

Is DTC “C1604” detected? YES >> Proceed to diagnosis procedure. Refer to STC-21, "Diagnosis Procedure".

NO >> INSPECTION END

Diagnosis Procedure

1.CHECK TERMINALS AND HARNESS CONECTORS

Check EPS control unit pin terminals for damage or loose connection with harness connector. If any items are damaged, repair or replace error-detected parts.

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace error-detected parts.

2.PERFORM SELF-DIAGNOSIS

1. Erase self-diagnostic results for “EPS”.With CONSULT-III


1. Erase self-diagnostic results for “EPS”.

2. Turn the ignition switch OFF, and then wait 10 seconds and more.

3. Perform self-diagnosis for “EPS”.

Is DTC “C1604” detected? YES >> Torque sensor is malfunctioning. Replace steering column assembly. Refer to ST-10, "Removal and Installation".

NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

    C1601 battery power supply
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always turn ignition switch OFF and wait at least 10 ...

    C1606 EPS motor
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always turn ignition switch OFF and wait at least 10 ...

    Other materials:

    P1778 step motor
    Description • The step motor's 4 aspects of ON/OFF change according to the signal from TCM. As a result, the flow of line pressure to primary pulley is changed and pulley ratio is controlled. • This diagnosis item is detected when electrical system is OK, but mechanical system is NG. • This ...

    Handling for Adhesive and Primer
    • Never use an adhesive that is past its usable date. Shelf life of this product is limited to six months after the date of manufacture. Carefully adhere to the expiration or manufacture date printed on the box. • Keep primers and adhesive in a cool, dry place. Ideally, they should be stored ...

    B210C starter control relay
    DTC Logic DTC DETECTION LOGIC NOTE: • If DTC B210C is displayed with DTC U1000, first perform the trouble diagnosis for DTC U1000. Refer to PCS-30, "DTC Logic". • When IPDM E/R power supply voltage is low (Approx. 7 - 8 V for about 1 second), the DTC B210C may be detected. DTC ...