Nissan Juke Service and Repair Manual : ANTI-HIJACK function does not operate

Diagnosis Procedure

1.CHECK “DOOR LOCK–UNLOCK SET” SETTING IN “WORK SUPPORT”

1. Select “DOOR LOCK” of “BCM” using CONSULT-III.

2. Select “DOOR LOCK-UNLOCK SET” in “WORK SUPPORT” mode.

3. Check “DOOR LOCK-UNLOCK SET” in “WORK SUPPORT” Refer to DLK-501, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK) (Without Super Lock)".

Is the inspection result normal? YES >> GO TO 2 NO >> Set “DOOR LOCK-UNLOCK SET” in “WORK SUPPORT” 2.REPLACE BCM

1. Replace BCM. Refer to BCS-161, "Removal and Installation".

2. Confirm the operation after replacement.

Is the result normal? YES >> INSPECTION END

NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

    Back door does not opened
    Diagnosis Procedure 1.CHECK BACK DOOR OPENER SWITCH Check back door opener switch. Refer to DLK-513, "Component Function Check". Is the inspection result normal? YES >> GO TO ...

    Vehicle speed sensing auto lock operation does not operate
    Diagnosis Procedure 1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mod ...

    Other materials:

    P1614 chain of IMMU-KEY
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PERFORM DTC CONFIRMATION PROCEDURE 1. Turn ignition switch ON. 2. Check DTC in “Self Diagnostic Result” mode of “ENGINE” using CONSULT-III. Is DTC detected? YES >> Refer to SEC-195, "Diagnosis Procedure". NO > ...

    P0197, P0198 EOT sensor
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test. 1. Turn ignition switch OFF and wait at least 10 seconds. 2. Turn ignition swit ...

    Squeak and rattle trouble diagnoses
    Work Flow CUSTOMER INTERVIEW Interview the customer if possible, to determine the conditions that exist when the noise occurs. Use the Diagnostic Worksheet during the interview to document the facts and conditions when the noise occurs and any of customer's comments; refer to DLK-302, &quo ...