Nissan Juke Service and Repair Manual : P range interlock door lock/unlock function does not operate

Diagnosis Procedure

1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT”

1. Select “DOOR LOCK” of “BCM” using CONSULT-III.

2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mode.

3. Check “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT”.

Refer to DLK-217, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK) (Without Super Lock)".

Is the inspection result normal? YES >> GO TO 2.

NO >> Set “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT”.

2.CHECK “AUTOMATIC DOOR LOCK SELECT” SETTING IN “WORK SUPPORT”

1. Select “DOOR LOCK” of “BCM” using CONSULT-III.

2. Select “AUTOMATIC DOOR LOCK SELECT” in “WORK SUPPORT” mode.

3. Check “AUTOMATIC DOOR LOCK SELECT” in “WORK SUPPORT”.

Refer to DLK-217, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK) (Without Super Lock)".

Is the inspection result normal? YES >> GO TO 3.

NO >> Set “AUTOMATIC DOOR LOCK SELECT” in “WORK SUPPORT”.

3.CHECK “AUTOMATIC DOOR UNLOCK SELECT” SETTING IN “WORK SUPPORT”

1. Select “DOOR LOCK” of “BCM” using CONSULT-III.

2. Select “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT” mode.

3. Check “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT”.

Refer to DLK-217, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK) (Without Super Lock)".

Is the inspection result normal? YES >> GO TO 4.

NO >> Set “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT”.

4.REPLACE BCM

1. Replace BCM. Refer to BCS-93, "Removal and Installation".

2. Confirm the operation after replacement.

Is the result normal? YES >> INSPECTION END

NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

    IGN off interlock door unlock function does not operate
    Diagnosis Procedure 1.CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT-III. 2. Select “AUTOMATIC LOCK/UNLOCK SELECT” i ...

    Hazard and buzzer reminder does not operate
    Diagnosis Procedure 1.CHECK DTC WITH BCM AND COMBINATION METER Check that DTC is not detected with BCM and combination meter. Is the inspection result normal? YES >> GO TO 2. NO-1 >& ...

    Other materials:

    P0137 HO2S2
    DTC Logic DTC DETECTION LOGIC The heated oxygen sensor 2 has a much longer switching time between rich and lean than the air fuel ratio (A/F) sensor 1. The oxygen storage capacity of the three way catalyst (manifold) causes the longer switching time. To judge the malfunctions of heated oxygen ...

    How to trickle charge (AC 110-120 volt) by L1 EVSE
    WARNING If you utilize a pacemaker or an implantable cardiovascular defibrillator (ICD), ensure you maintain a minimum distance of 6 inches (15 cm) from the EVSE (Electric Vehicle Supply Equipment) at all times to prevent potential electromagnetic interference. Before initiat ...

    B261A Push-button ignition switch
    DTC Logic DTC DETECTION LOGIC NOTE: • If DTC B261A is displayed with DTC U1000, first perform the trouble diagnosis for DTC U1000. Refer to BCS-83, "DTC Logic". • If DTC B261A is displayed with DTC U1010, first perform the trouble diagnosis for DTC U1010. Refer to BCS-84, &qu ...