Nissan Juke Service and Repair Manual : Insufficient heating

Description

Symptom
• Insufficient heating
• No warm air comes out. (Air flow volume is normal.)

Diagnosis Procedure

NOTE

:
Perform self-diagnoses with CONSULT-III before performing symptom diagnosis. If any DTC is detected, perform the corresponding diagnosis.

1.CHECK COOLING SYSTEM

1. Check engine coolant level and check for leakage. Refer to CO-11, "Inspection".

2. Check radiator cap. Refer to CO-15, "RADIATOR CAP : Inspection".

3. Check water flow sounds of the engine coolant. Refer to CO-12, "Refilling".

Is the inspection result normal? YES >> GO TO 2.

NO >> Refill engine coolant and repair or replace the parts depending on the inspection results.

2.CHECK HEATER HOSE

Check installation of heater hose by visually or touching.

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace parts depending on the inspection results.

3.CHECK HEATER CORE

1. Check temperature of inlet hose and outlet hose of heater core.

2. Check that inlet side of heater core is hot and the outlet side is slightly lower than/almost equal to the inlet side.

CAUTION:
Always perform the temperature inspection in a short period of time because the engine coolant temperature is very hot.

Is the inspection result normal?

YES >> GO TO 4.

NO >> Replace heater core. Refer to HA-116, "HEATER CORE : Removal and Installation".

4.CHECK AIR LEAKAGE FROM EACH DUCT

Check duct and nozzle, etc. of the air conditioning system for air leakage.

Is the inspection result normal? YES >> GO TO 5.

NO >> Repair or replace parts depending on the inspection results.

5.CHECK SETTING OF TEMPERATURE SETTING TRIMMER

1. Check setting value of temperature setting trimmer. Refer to HAC-48, "Temperature Setting Trimmer".

2. Check that temperature setting trimmer is set to “− direction”.

NOTE

:
The control temperature can be set by the temperature setting trimmer.

3. Set difference between the set temperature and control temperature to “0”.

Are the symptoms solved? YES >> INSPECTION END

NO >> Replace A/C auto amp. Refer to HAC-91, "Removal and Installation".

    Insufficient cooling
    Description Symptom • Insufficient cooling • No cool air comes out. (Air flow volume is normal.) Diagnosis Procedure NOTE: Perform self-diagnoses with CONSULT-III before performing symptom d ...

    Compressor dose dot operate
    Description SYMPTOM Compressor dose not operate. Diagnosis Procedure NOTE: • Perform self-diagnoses with CONSULT-III before performing symptom diagnosis. If any DTC is detected, perform the ...

    Other materials:

    Inspection
    INSPECTION AFTER REMOVAL Check the following items, and replace the part if necessary. • Move joint up/down, left/right, and in the axial directions. Check for motion that is not smooth and for significant looseness. • Check boot for cracks, damage, and leakage of grease. • Check the ...

    Interior room lamp control circuit
    Description Controls each interior room lamp (ground side) by PWM signal. NOTE: PWM signal control period is approximately 250 Hz (in the gradual brightening/dimming). Component Function Check CAUTION: Before performing the diagnosis, check that the following are normal. • Interior room ...

    Drive belt auto tensioner and idler pulley
    Exploded View 1. Front cover 2. Drive belt auto-tensioner : N·m (kg-m, ft-lb) Removal and Installation Removal 1. Loosen mounting bolt and remove drive belt auto-tensioner. Installation Install in the reverse order of removal. CAUTION: When installing drive belt auto-tensioner, be ...