Nissan Juke Service and Repair Manual : BCM (body control module)
Removal and Installation
CAUTION:
Before replacing BCM, perform “READ CONFIGURATION� to save or print current
vehicle specification.
Refer to BCS-150, "Description".
REMOVAL (RHD MODELS)
1. Remove glove box assembly. Refer to IP-13, "Removal and Installation".
2. Remove harness clip.
3. Remove BCM mounting screws.
4. Remove BCM and disconnect the connectors.
5. Remove relays and relay mounting bracket from BCM.
REMOVAL (LHD MODELS)
1. Remove instrument lower panel. Refer to IP-13, "Removal and Installation".
2. Remove harness clip.
3. Remove BCM mounting screws.
4. Remove BCM and disconnect the connectors.
5. Remove relays and relay mounting bracket from BCM.
INSTALLATION
Install in the reverse order of removal.
CAUTION:
• Be sure to perform “WRITE CONFIGURATION� when replacing BCM.
• Be sure to perform the system initialization (NATS) when replacing BCM. Refer to BCS-151, "Work Procedure".
Combination switch
Exploded View
1. Combination switch
2. Combination switch connector
Removal and Installation
REMOVAL
1. Remove steering column cover. Refer to IP-13, "Removal and
Installation".
2 ...
Other materials:
P0335 CKP sensor (POS)
DTC Logic
DTC DETECTION LOGIC
Diagnosis Procedure
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit
Inspection".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or ...
Idle air volume learning
Description
Idle Air Volume Learning is a function of ECM to learn the idle air volume
that keeps each engine idle speed
within the specific range. It must be performed under any of the following
conditions:
• Each time electric throttle control actuator or ECM is replaced.
• Idle speed ...
System setting
Temperature Setting Trimmer
DESCRIPTION
If the temperature felt by the customer is different from the air flow
temperature controlled by the temperature
setting, the A/C auto amp. control temperature can be adjusted to compensate for
the temperature setting.
HOW TO SET
With CONSULT-III
P ...