Nissan Juke Service and Repair Manual : Auto retractable door mirror does not operate

Diagnosis Procedure

1.CHECK INTELLIGENT KEY AND DOOR REQUEST SWITCH OPERATION

Check operation of Intelligent Key and door request switch.

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace the malfunctioning parts.

2.CHECK DOOR MIRROR (OPEN/CLOSE MOTOR) CIRCUIT

Check door mirror (open/close motor) circuit.

Refer to MIR-25, "Component Function Check".

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace the malfunctioning parts.

3.CHECK AUTO RETRACTABLE DOOR MIRROR CIRCUIT

Check auto retractable door mirror circuit.

Refer to MIR-30, "Component Function Check".

Is the inspection result normal? YES >> GO TO 4.

NO >> Repair or replace the malfunctioning parts.

4.CONFIRM THE OPERATION

Confirm the operation again.

Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

NO >> GO TO 1.

    Electric foldable door mirror does not operate
    Diagnosis Procedure 1.CHECK DOOR MIRROR (OPEN/CLOSE MOTOR) CIRCUIT Check door mirror (open/close motor) circuit. Refer to MIR-25, "Component Function Check". Is the inspection result ...

    Squeak and rattle trouble diagnoses
    Work Flow CUSTOMER INTERVIEW Interview the customer if possible, to determine the conditions that exist when the noise occurs. Use the Diagnostic Worksheet during the interview to document the ...

    Other materials:

    Component parts
    Component Parts Location 1. Intelligent Key warning buzzer 2. Remote keyless entry receiver 3. Inside key antenna (instrument center) 4. TCM Refer to TM-133, "CVT CONTROL SYSTEM : TCM" (RE0F10B models) or TM-316, "CVT CONTROL SYSTEM : TCM" (RE0F11A models) 5. Push-bu ...

    Diagnosis system (audio unit)
    Models with usb connection function MODELS WITH USB CONNECTION FUNCTION : On Board Diagnosis Function Self-diagnosis mode can check the following items. METHOD OF STARTING 1. Start the engine. 2. Turn OFF audio. 3. While pressing the “SET UP” switch, turn the MENU dial counterclockwise 3 cl ...

    Diagnosis and repair workflow
    Work Flow OVERALL SEQUENCE DETAILED FLOW 1.INTERVIEW FOR MALFUNCTION Interview the symptom to the customer. >> GO TO 2. 2.SYMPTOM CHECK Check the symptom from the customer's information. >> GO TO 3. 3.BASIC INSPECTION Check the operation of each part. Check that any s ...