Nissan Juke Service and Repair Manual : Auto operation does not operate but manual operate normally (driver side)

Diagnosis Procedure

1.PERFORM INITIALIZATION PROCEDURE

Initialization procedure is executed and operation is confirmed.

Refer to PWC-16, "Work Procedure".

Is the inspection result normal? YES >> INSPECTION END

NO >> GO TO 2.

2.CHECK ENCODER CIRCUIT

Check encoder circuit.

Refer to PWC-30, "Component Function Check".

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace the malfunctioning parts.

3.CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal? YES >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

NO >> GO TO 1.

    Driver side power window does not operate
    Diagnosis Procedure 1.CHECK FRONT POWER WINDOW MOTOR (DRIVER SIDE) Check front power window motor (driver side). Refer to PWC-26, "DRIVER SIDE : Component Function Check". Is the ins ...

    Anti-pinch system does not operate normally (driver side)
    Diagnosis Procedure 1.CHECK POWER WINDOW AUTO OPERATION Check AUTO operation when anti-pinch function does not operate. Is the inspection result normal? YES >> GO TO 2. NO >> Refe ...

    Other materials:

    B2615 blower relay circuit
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PERFORM DTC CONFIRMATION PROCEDURE 1. Turn ignition switch ON under the following conditions, and wait for 1 second or more. CVT models - Selector lever is in the P or N position - Do not depress brake pedal M/T models - Do no ...

    B26F1 ignition relay
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PERFORM DTC CONFIRMATION PROCEDURE 1. Turn ignition switch ON under the following conditions, and wait for 2 seconds or more. CVT models - Selector lever is in the P or N position - Do not depress brake pedal M/T models - Do n ...

    Operation inspection
    Work Procedure The purpose of the operational check is to check that the individual system operates normally. Check condition : Engine running at normal operating temperature. 1.CHECK BLOWER MOTOR 1. Operate fan control dial. 2. Check that fan speed changes. Check operation for all fan speeds ...