Nissan Juke Service and Repair Manual : EPS warning lamp does not turn off
Description
EPS warning lamp does not turn OFF several seconds after engine started.
Diagnosis Procedure
1.PERFORM SELF-DIAGNOSIS
With CONSULT-III
1. Turn the ignition switch OFF to ON.
2. Perform “EPS” self-diagnosis.
Is any DTC detected? YES >> Check the DTC. Refer to STC-14, "DTC Index".
NO >> GO TO 2.
2.CHECK EPS WARNING LAMP
Perform the trouble diagnosis of EPS warning lamp. Refer to STC-26, "Diagnosis Procedure".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair or replace the specific malfunctioning part.
3.CHECK EPS CONTROL UNIT POWER SUPPLY AND GROUND CIRCUIT
Perform the trouble diagnosis of EPS control unit power supply and ground. Refer to STC-19, "Diagnosis Procedure".
Is the inspection result normal? YES >> Check that there is no malfunction in each harness connector pin terminal or disconnection.
NO >> Repair or replace the specific malfunctioning part.
EPS warning lamp does not turn on
Description
EPS warning lamp does not turn ON when turning ignition switch ON from OFF.
(Check the illumination of the
EPS warning lamp.)
Diagnosis Procedure
1.CHECK EPS WARNING LAMP
Perform th ...
Steering wheel turning force is heavy or light
Description
Steering wheel turning force is heavy or light.
Diagnosis Procedure
1.CHECK THE ILLUMINATION OF THE EPS WARNING LAMP
Check that the EPS warning lamp turns ON when ignition switch turns ...
Other materials:
Vehicle jerks during
Description
The vehicle jerks when ABS function and EBD function operates.
Diagnosis Procedure
1.CHECK SYMPTOM
Check that the vehicle jerks when ABS function and EBD function operates.
Is the inspection result normal?
YES >> Normal
NO >> GO TO 2.
2.PERFORM SELF-DIAGNOSIS
Wit ...
Diagnosis system (IPDM E/R)
Consult-III Function (IPDM E/R)
APPLICATION ITEM
CONSULT-III performs the following functions via CAN communication with IPDM
E/R.
SELF DIAGNOSTIC RESULT
Refer to PCS-25, "DTC Index".
DATA MONITOR
Monitor item
ACTIVE TEST
Test item
...
Intelligent Key system (if so equipped)
WARNING
• Radio waves could adversely affect electric medical equipment. Those who
use a pacemaker should contact the electric medical equipment manufacturer for the
possible influences before use.
• The Intelligent Key transmits radio waves when the buttons are pushed. The FAA