Nissan Juke Service and Repair Manual : EPS warning lamp does not turn off

Description

EPS warning lamp does not turn OFF several seconds after engine started.

Diagnosis Procedure

1.PERFORM SELF-DIAGNOSIS

1. Turn the ignition switch OFF to ON.With CONSULT-III


1. Turn the ignition switch OFF to ON.

2. Perform “EPS” self-diagnosis.

Is any DTC detected? YES >> Check the DTC. Refer to STC-14, "DTC Index".

NO >> GO TO 2.

2.CHECK EPS WARNING LAMP

Perform the trouble diagnosis of EPS warning lamp. Refer to STC-26, "Diagnosis Procedure".

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace the specific malfunctioning part.

3.CHECK EPS CONTROL UNIT POWER SUPPLY AND GROUND CIRCUIT

Perform the trouble diagnosis of EPS control unit power supply and ground. Refer to STC-19, "Diagnosis Procedure".

Is the inspection result normal? YES >> Check that there is no malfunction in each harness connector pin terminal or disconnection.

NO >> Repair or replace the specific malfunctioning part.

    EPS warning lamp does not turn on
    Description EPS warning lamp does not turn ON when turning ignition switch ON from OFF. (Check the illumination of the EPS warning lamp.) Diagnosis Procedure 1.CHECK EPS WARNING LAMP Perform th ...

    Steering wheel turning force is heavy or light
    Description Steering wheel turning force is heavy or light. Diagnosis Procedure 1.CHECK THE ILLUMINATION OF THE EPS WARNING LAMP Check that the EPS warning lamp turns ON when ignition switch turns ...

    Other materials:

    Vehicle jerks during
    Description The vehicle jerks when ABS function and EBD function operates. Diagnosis Procedure 1.CHECK SYMPTOM Check that the vehicle jerks when ABS function and EBD function operates. Is the inspection result normal? YES >> Normal NO >> GO TO 2. 2.PERFORM SELF-DIAGNOSIS Wit ...

    Diagnosis system (IPDM E/R)
    Consult-III Function (IPDM E/R) APPLICATION ITEM CONSULT-III performs the following functions via CAN communication with IPDM E/R. SELF DIAGNOSTIC RESULT Refer to PCS-25, "DTC Index". DATA MONITOR Monitor item ACTIVE TEST Test item ...

    Intelligent Key system (if so equipped)
    WARNING • Radio waves could adversely affect electric medical equipment. Those who use a pacemaker should contact the electric medical equipment manufacturer for the possible influences before use. • The Intelligent Key transmits radio waves when the buttons are pushed. The FAA advises that ...