Nissan Juke Service and Repair Manual : System initialization

Description

If any of the following operations are performed, the initialization is necessary for normal operation of power window system.

• Disconnection and connection of battery cable from negative terminal.

• When power window main switch replaced.

• Electric power supply to power window main switch or power window motor (driver side) is interrupted by blown fuse or disconnection and connection of the negative terminal of battery, etc.

• Disconnection and connection of power window main switch harness connector.

• Removal of power window motor (driver side) from regulator assembly.

• Operation of regulator assembly as an independent unit.

• Removal and installation of glass.

• Removal and installation of door glass run.

CAUTION:
The following specified operations can not be performed under the non-initialized condition.

• Auto-up operation
• Anti-pinch function

Work Procedure

1.STEP 1

1. Turn ignition switch ON.

2. Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open)
3. Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 2 seconds or more.

4. Check that AUTO-UP function operates normally.

>> GO TO 2.

2.STEP 2

Check anti-pinch function. Refer to PWC-17, "Work Procedure".

>> END

    Additional service when replacing control unit
    Description When the control unit replaced, the initialization in necessary for normal operation of power window system. CAUTION: The following specified operations can not be performed under t ...

    Check anti-pinch function
    Description If any of the following operations are performed, the initialization is necessary for normal operation of antipinch function. • Disconnection and connection of battery cable from ne ...

    Other materials:

    B1068, B1073 passenger air bag module
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.CHECK SELF-DIAG RESULT With CONSULT-III 1. Turn ignition switch ON. 2. Perform “Self Diagnostic Result” mode of “AIR BAG” using CONSULT-III. Without CONSULT-III 1. Turn ignition switch ON. 2. Check the air bag warning lamp statu ...

    Precaution
    Precautions for Trouble Diagnosis CAUTION: • Never apply 7.0 V or more to the measurement terminal. • Use a tester with open terminal voltage of 7.0 V or less. • Turn the ignition switch OFF and disconnect the battery cable from the negative terminal when checking the harness. Precautions fo ...

    Door lock actuator