Nissan Juke Service and Repair Manual : System setting
Temperature Setting Trimmer
DESCRIPTION
If the temperature felt by the customer is different from the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.
HOW TO SET
With CONSULT-III
Perform “TEMP SET CORRECT” of HVAC work support item.
NOTE
:
• When −3.0°C is corrected on the temperature setting set as 25.0°C the
temperature controlled by A/C auto
amp. is 25.0°C −3.0°C = 22.0°C and the temperature becomes lower than the
temperature setting.
• When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the difference between the set temperature and control temperature may be cancelled.
Inlet Port Memory Function (REC)
DESCRIPTION
• If the ignition switch is turned to the OFF position while the intake switch is set to ON (recirculation), “Perform the memory” or “Do not perform the memory” of intake switch ON (recirculation) condition can be selected.
• If “Perform the memory” was set, the intake switch will be ON (recirculation) when turning the ignition switch to the ON position again.
• If “Do not perform the memory” was set, the air inlets will be controlled automatically when turning the ignition switch to the ON position again.
HOW TO SET
With CONSULT-III
Perform the “REC MEMORY SET” of HVAC work support item
NOTE
:
When the battery cable is disconnected from the negative terminal or when the
battery voltage becomes 10 V
or less, the setting of the REC memory function may be cancelled.
Inlet Port Memory Function (FRE)
DESCRIPTION
• If the ignition switch is turned to the OFF position while the intake switch is set to OFF (fresh air intake), “Perform the memory” or “Do not perform the memory” of intake switch OFF (fresh air intake) condition can be selected.
• If “Perform the memory” was set, the intake switch will be OFF (fresh air intake) when turning the ignition switch to the ON position again.
• If “Do not perform the memory” was set, the air inlets will be controlled automatically when turning the ignition switch to the ON position again.
HOW TO SET
With CONSULT-III
Perform the “FRE MEMORY SET” of HVAC work support item.
NOTE
:
When the battery cable is disconnected from the negative terminal or when the
battery voltage becomes 10 V
or less, the setting of the FRE memory function may be cancelled.
Operation inspection
Work Procedure The purpose of the operational check is to check that the individual system operates normally. Check condition : Engine running at normal operating temperature. 1.CHECK MEMORY FUNC ...Other materials:
Rear disc brake
Brake pad : Inspection and Adjustment
INSPECTION
Check brake pad wear thickness from an inspection hole on cylinder
body. Check using a scale if necessary.
Wear thickness : Refer to BR-71, "Rear Disc Brake".
ADJUSTMENT
Burnish contact surfaces between disc rotor and brake pads acco ...
Removal and installation
MULTI DISPLAY UNIT
Exploded View
REMOVAL
Refer to IP-12, "Exploded View".
DISASSEMBLY
1. Silencer tape
2. Multi display unit
3. Silencer tape
4. Clip
5. Control finisher
Removal and Installation
REMOVAL
Refer to IP-12, "Exploded View".
CAUTION:
• When perfo ...
Keyfob id registration
Description
Perform the following procedure after BCM is replaced or when new keyfob ID
is registered
NOTE:
When registering the keyfob ID, perform only one procedure to simultaneously
register both ID (IMMOBILIZER
ID and keyfob ID).
Work Procedure
1.STEP 1
Close all doors.
>> GO ...