Nissan Juke Service and Repair Manual : System setting

Temperature Setting Trimmer

DESCRIPTION

If the temperature felt by the customer is different from the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.

HOW TO SET

Perform “TEMP SET CORRECT” of HVAC work support item.With CONSULT-III


Perform “TEMP SET CORRECT” of HVAC work support item.

NOTE:


NOTE

:
• When −3.0°C is corrected on the temperature setting set as 25.0°C the temperature controlled by A/C auto amp. is 25.0°C −3.0°C = 22.0°C and the temperature becomes lower than the temperature setting.

• When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the difference between the set temperature and control temperature may be cancelled.

Inlet Port Memory Function (REC)

DESCRIPTION

• If the ignition switch is turned to the OFF position while the intake switch is set to ON (recirculation), “Perform the memory” or “Do not perform the memory” of intake switch ON (recirculation) condition can be selected.

• If “Perform the memory” was set, the intake switch will be ON (recirculation) when turning the ignition switch to the ON position again.

• If “Do not perform the memory” was set, the air inlets will be controlled automatically when turning the ignition switch to the ON position again.

HOW TO SET

Perform the “REC MEMORY SET” of HVAC work support itemWith CONSULT-III


Perform the “REC MEMORY SET” of HVAC work support item

NOTE:


NOTE

:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the REC memory function may be cancelled.

Inlet Port Memory Function (FRE)

DESCRIPTION

• If the ignition switch is turned to the OFF position while the intake switch is set to OFF (fresh air intake), “Perform the memory” or “Do not perform the memory” of intake switch OFF (fresh air intake) condition can be selected.

• If “Perform the memory” was set, the intake switch will be OFF (fresh air intake) when turning the ignition switch to the ON position again.

• If “Do not perform the memory” was set, the air inlets will be controlled automatically when turning the ignition switch to the ON position again.

HOW TO SET

Perform the “FRE MEMORY SET” of HVAC work support item.With CONSULT-III


Perform the “FRE MEMORY SET” of HVAC work support item.

NOTE:


NOTE

:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of the FRE memory function may be cancelled.

    Operation inspection
    Work Procedure The purpose of the operational check is to check that the individual system operates normally. Check condition : Engine running at normal operating temperature. 1.CHECK MEMORY FUNC ...

    Other materials:

    Rear disc brake
    Brake pad : Inspection and Adjustment INSPECTION Check brake pad wear thickness from an inspection hole on cylinder body. Check using a scale if necessary. Wear thickness : Refer to BR-71, "Rear Disc Brake". ADJUSTMENT Burnish contact surfaces between disc rotor and brake pads acco ...

    Removal and installation
    MULTI DISPLAY UNIT Exploded View REMOVAL Refer to IP-12, "Exploded View". DISASSEMBLY 1. Silencer tape 2. Multi display unit 3. Silencer tape 4. Clip 5. Control finisher Removal and Installation REMOVAL Refer to IP-12, "Exploded View". CAUTION: • When perfo ...

    Keyfob id registration
    Description Perform the following procedure after BCM is replaced or when new keyfob ID is registered NOTE: When registering the keyfob ID, perform only one procedure to simultaneously register both ID (IMMOBILIZER ID and keyfob ID). Work Procedure 1.STEP 1 Close all doors. >> GO ...