Nissan Juke Service and Repair Manual : Engine smokes when revved

Description

CHART 20: ENGINE SMOKES WHEN REVVED

Diagnosis Procedure

1.CHECK ENGINE OIL

Check the grade of engine oil. Refer to LU-25, "Inspection".

Is the inspection result normal? YES >> GO TO 2.

NO >> Replace engine oil. Refer to LU-26, "Refilling".

2.CHECK ENGINE OIL LEVEL

Is the engine oil level correct? Yes or No Yes >> GO TO 3.

No >> Top up the oil.

3.CHECK ECM POWER SUPPLY AND GROUND CIRCUIT

Check ECM power supply and ground circuit. Refer to EC-908, "Component Inspection".

Is the inspection result normal? YES >> GO TO 4.

NO >> Repair or replace harness or connector.

4.CHECK WIRING HARNESS

Visually check the condition of the engine wiring harness.

Is the inspection result normal? YES >> GO TO 5.

NO >> Repair or replace harness or connector.

5.CHECK MASS AIR FLOW SENSOR

Check mass air flow sensor. Refer to EC-902, "Component Inspection".

Is the inspection result normal? YES >> INSPECTION END

NO >> Repair or replace.

    Engine emits blue smoke
    Description CHART 19: ENGINE EMITS BLUE SMOKE Diagnosis Procedure 1.CHECK ENGINE OIL Check the grade of engine oil. Refer to LU-33, "Inspection". Is the inspection result normal? YES ...

    Engine emits white smoke (especially when starting)
    Description CHART 21: ENGINE EMITS WHITE SMOKE (ESPECIALLY WHEN STARTING) Diagnosis Procedure 1.CHECK FUEL Check that the fuel reservoir is correctly filled and with the right fuel. >> GO ...

    Other materials:

    Door locks/unlocks precaution
    • Do not push the door handle request switch with the Intelligent Key held in your hand as illustrated. The close distance to the door handle will cause the Intelligent Key system to have difficulty recognizing that the Intelligent Key is outside the vehicle. • After locking with the door h ...

    Erratic acceleration
    Description CHART 10: Erratic acceleration Diagnosis Procedure 1.CHECK ECM POWER SUPPLY AND GROUND CIRCUIT Check ECM power supply and ground circuit. Refer to EC-885, "Diagnosis Procedure". Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace ha ...

    Interior room lamp control circuit
    Description Controls each interior room lamp (ground side) by PWM signal. NOTE: PWM signal control period is approximately 250 Hz (in the gradual brightening/dimming). Component Function Check CAUTION: Before performing the diagnosis, check that the following are normal. • Interior room l ...