Nissan Juke Service and Repair Manual : B1180 lap Pre-tensioner RH

DTC Logic

DTC CONFIRMATION PROCEDURE


DTC CONFIRMATION PROCEDURE

1.CHECK SELF-DIAGNOSTIC RESULT

1. Turn ignition switch ON.With CONSULT-III


1. Turn ignition switch ON.

2. Perform “Self Diagnostic Result” mode of “AIR BAG” using CONSULT-III.

1. Turn ignition switch ON.Without CONSULT-III


1. Turn ignition switch ON.

2. Check the air bag warning lamp status. Refer to SRC-12, "On Board Diagnosis Function".

NOTE

:
SRS does not enter diagnosis mode if no malfunction is detected in user mode.

Is malfunctioning part detected? YES >> Refer to SRC-133, "Diagnosis Procedure".

NO >> INSPECTION END

Diagnosis Procedure

WARNING:
• Before servicing, turn ignition switch OFF, disconnect battery negative terminal and wait at least 3 minutes. (To discharge backup capacitor.) • Never use unspecified tester or other measuring device.

1.CHECK HARNESS CONNECTOR

Check the harness connector.

Is the inspection result normal? YES >> GO TO 2.

NO >> Replace harness connector.

2.CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal? YES >> GO TO 3.

NO >> Replace wiring harness.

3.REPLACE LAP PRE-TENSIONER LH

1. Replace lap pre-tensioner LH. Refer to SR-33, "Removal and Installation".

2. Perform DTC confirmation procedure. Refer to SRC-133, "DTC Logic".

Is DTC detected? YES >> GO TO 4.

NO >> INSPECTION END

4.REPLACE AIR BAG DIAGNOSIS SENSOR UNIT

1. Replace air bag diagnosis sensor unit. Refer to SR-30, "Removal and Installation".

2. Perform DTC confirmation procedure. Refer to SRC-133, "DTC Logic".

Is DTC detected? YES >> GO TO 1.

NO >> INSPECTION END

    B1179 lap Pre-tensioner RH
    DTC Logic DTC CONFIRMATION PROCEDURE 1.CHECK SELF-DIAGNOSTIC RESULT With CONSULT-III 1. Turn ignition switch ON. 2. Perform “Self Diagnostic Result” mode of “AIR BAG” using CONSULT-III. With ...

    B1182 lap Pre-tensioner LH
    DTC Logic DTC CONFIRMATION PROCEDURE 1.CHECK SELF-DIAGNOSTIC RESULT With CONSULT-III 1. Turn ignition switch ON. 2. Perform “Self Diagnostic Result” mode of “AIR BAG” using CONSULT-III. With ...

    Other materials:

    P181F incomplete calibration
    DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.PRECONDITIONING If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test. >> GO TO 2. 2.DTC REPRODUCTION PROCEDURE With ...

    General Precautions
    WARNING: When replacing fuel line parts, be sure to observe the following. • Put a ???CAUTION: FLAMMABLE??? sign in the workshop. • Be sure to work in a well ventilated area and furnish workshop with a CO2 fire extinguisher. • Never smoke while servicing fuel system. Keep open flames and spa ...

    Power supply and ground circuit
    Combination meter COMBINATION METER : Diagnosis Procedure 1.CHECK FUSE Check for blown fuses. Is the inspection result normal? YES >> GO TO 2. NO >> Be sure to eliminate cause of malfunction before installing new fuse. 2.CHECK POWER SUPPLY CIRCUIT Check voltage between comb ...