Nissan Juke Service and Repair Manual : Throttle valve closed position learning

Description

Throttle Valve Closed Position Learning is an operation to learn the fully closed position of the throttle valve by monitoring the throttle position sensor output signal. It must be performed each time harness connector of electric throttle control actuator or ECM is disconnected.

Electric throttle control actuator is removed.

Electric throttle control actuator is replaced.

ECM is replaced.

NOTE

:
The necessary operation is different depending on the operation result of ECM data save or write. Always perform the operation according to procedures. Refer to EC-882, "Work Procedure".

Work Procedure

1.START

1. Make sure that accelerator pedal is fully released.

2. Turn ignition switch ON and wait at least 15 seconds.

Make sure that throttle valve moves during the above 15 seconds by confirming the operating sound.

3. Turn ignition switch OFF and wait at least 4 minutes.

4. Turn ignition switch ON.

>> END

    EGR volume control valve closed position learning
    Description EGR Volume Control Valve Closed Position Learning is an operation to learn the fully closed position of the EGR volume control valve by monitoring the EGR volume control valve control ...

    Service regeneration
    Description Service Regeneration is performed with CONSULT-III to reduce particulate matter in diesel particulate filter. Service Regeneration should be performed in the following cases. ECM ...

    Other materials:

    Wiring diagram
    Security control system LHD LHD : Wiring Diagram For connector terminal arrangements, harness layouts, and alphabets in a (option abbreviation; if not described in wiring diagram), refer to GI-12, "Connector Information/Explanation of Option Abbreviation". RHD RHD : Wirin ...

    To protect your vehicle from corrosion
    Wash and wax your vehicle often to keep the vehicle clean. Always check for minor damage to the paint and repair it as soon as possible.   Keep drain holes at the bottom of the doors open to avoid water accumulation. Check the underbody for accumulation of sand, dirt or salt. If ...

    Check anti-pinch function
    Description If any of the following operations are performed, the initialization is necessary for normal operation of antipinch function. Disconnection and connection of battery cable from negative terminal. When power window main switch replaced. Electric power supply to power window ...