Nissan Juke Service and Repair Manual : Removal and installation
Positive crankcase ventilation
Inspection 1.CHECK PCV VALVE With engine running at idle, remove PCV valve from rocker cover. A properly working valve makes a hissing noise as air passes through it. A strong vacuum should be fel ...ECM
Removal and Installation REMOVAL 1. Remove fusible link bracket. Keep a service area. 2. Disconnect ECM harness connectors. Refer to PG-4, "Harness Connector". 3. Remove ECM mounting nut ...Other materials:
Camshaft valve clearance
Inspection and Adjustment
INSPECTION
Perform inspection as follows after removal, installation or replacement of
camshaft or valve-related parts, or if
there is unusual engine conditions regarding valve clearance.
1. Remove rocker cover. Refer to EM-178, "Removal and Installation".
...
U1010 control unit (can)
Description
Initial diagnosis of A/C auto amp.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM SELF-DIAGNOSIS
With CONSULT-III
1. Turn ignition switch ON.
2. Select “Self Diagnostic Result” mode of “HVAC” using CONSULT-.III
3. Check DTC.
Is DTC detected?
YES >> ...
Cylinder Head
VALVE DIMENSIONS
VALVE GUIDE
VALVE SEAT
*1: Diameter made by intersection point of conic angles “α1” and “α2”
*2: Diameter made by intersection point of conic angles “α2” and “α3”
*3: Machining data
VALVE SPRING
...