Nissan Juke Service and Repair Manual : Door does not lock/unlock with keyfob

Diagnosis Procedure

1.CHECK POWER DOOR LOCK OPERATION

Check power door lock operation.

Does door lock/unlock with door lock and unlock switch? YES >> GO TO 2.

NO >> Go to DLK-415, "ALL DOOR : Diagnosis Procedure".

2.CHECK REMOTE KEYLESS ENTRY RECEIVER

Check remote keyless entry receiver.

Refer to DLK-404, "Component Function Check".

Is the inspection result normal? YES >> GO TO 3.

NO >> Repair or replace the malfunctioning parts.

3.CHECK KEYFOB BATTERY

Check keyfob battery.

Refer to DLK-403, "Component Function Check".

Is the inspection result normal? YES >> GO TO 4.

NO >> Repair or replace the malfunctioning parts.

4.REPLACE BCM

1. Replace BCM. Refer to BCS-161, "Removal and Installation".

2. Confirm the operation after replacement.

Is the result normal? YES >> INSPECTION END

NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".

    Door lock status indicator does not illuminate
    Diagnosis Procedure 1.CHECK DOOR LOCK STATUS INDICATOR Check door lock status indicator. Refer to DLK-395, "Component Function Check". Is the inspection result normal? YES >> ...

    Other materials:

    Precaution
    Precautions for Suspension When installing rubber bushings, the final tightening must be carried out under unladen conditions with tires on ground. Spilled oil might shorten the life of rubber bushings. Be sure to wipe off any spilled oil. - Unladen conditions mean that fuel, engine coolant ...

    Precaution for Supplemental Restraint System (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER"
    The Supplemental Restraint System such as AIR BAG and SEAT BELT PRE-TENSIONER, used along with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger for certain types of collision. Information necessary to service the system safely is include ...

    Precaution Necessary for Steering Wheel Rotation after Battery Disconnect
    NOTE: Before removing and installing any control units, first turn the ignition switch to the LOCK position, then disconnect both battery cables. After finishing work, confirm that all control unit connectors are connected properly, then re-connect both battery cables. Always use CONS ...