Nissan Juke Service and Repair Manual : B1183 lap Pre-tensioner LH

DTC Logic

DTC CONFIRMATION PROCEDURE


DTC CONFIRMATION PROCEDURE

1.CHECK SELF-DIAGNOSTIC RESULT

1. Turn ignition switch ON.With CONSULT-III


1. Turn ignition switch ON.

2. Perform Self Diagnostic Result mode of AIR BAG using CONSULT-III.

1. Turn ignition switch ON.Without CONSULT-III


1. Turn ignition switch ON.

2. Check the air bag warning lamp status. Refer to SRC-12, "On Board Diagnosis Function".

NOTE

:
SRS does not enter diagnosis mode if no malfunction is detected in user mode.

Is malfunctioning part detected? YES >> Refer to SRC-135, "Diagnosis Procedure".

NO >> INSPECTION END

Diagnosis Procedure

WARNING:
Before servicing, turn ignition switch OFF, disconnect battery negative terminal and wait at least 3 minutes. (To discharge backup capacitor.) Never use unspecified tester or other measuring device.

1.CHECK HARNESS CONNECTOR

Check the harness connector.

Is the inspection result normal? YES >> GO TO 2.

NO >> Replace harness connector.

2.CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal? YES >> GO TO 3.

NO >> Replace wiring harness.

3.REPLACE LAP PRE-TENSIONER LH

1. Replace lap pre-tensioner LH. Refer to SR-33, "Removal and Installation".

2. Perform DTC confirmation procedure. Refer to SRC-135, "DTC Logic".

Is DTC detected? YES >> GO TO 4.

NO >> INSPECTION END

4.REPLACE AIR BAG DIAGNOSIS SENSOR UNIT

1. Replace air bag diagnosis sensor unit. Refer to SR-30, "Removal and Installation".

2. Perform DTC confirmation procedure. Refer to SRC-135, "DTC Logic".

Is DTC detected? YES >> GO TO 1.

NO >> INSPECTION END

    B1182 lap Pre-tensioner LH
    DTC Logic DTC CONFIRMATION PROCEDURE 1.CHECK SELF-DIAGNOSTIC RESULT With CONSULT-III 1. Turn ignition switch ON. 2. Perform Self Diagnostic Result mode of AIR BAG using CONSULT-III. With ...

    B1184 lap Pre-tensioner LH
    DTC Logic DTC CONFIRMATION PROCEDURE 1.CHECK SELF-DIAGNOSTIC RESULT With CONSULT-III 1. Turn ignition switch ON. 2. Perform Self Diagnostic Result mode of AIR BAG using CONSULT-III. With ...

    Other materials:

    Diagnosis system (combination meter)
    On Board Diagnosis Function ON BOARD DIAGNOSIS ITEM The combination meter allows the following diagnosis items with the on-board diagnosis function. METHOD OF STARTING 1. Turn ignition switch ON, and switch the trip meter to trip A or trip B. 2. Turn ignition switch OFF. 3. While pre ...

    Antenna base
    Exploded View 1. Antenna rod 2. Antenna base : Nm (kg-m, in-lb) Removal and Installation REMOVAL 1. Remove headlining. Refer to INT-26, "Exploded View". 2. Disconnect antenna feeder connector. 3. Remove nut to remove antenna base. INSTALLATION Install in the reverse order o ...

    A/C switch